Signet 73007524 power supply for signet 2551 magmeter. Signet 2552 metal magmeter flow sensors the signet 2552 metal magmeter from georg fischer features allstainless steel construction. Gf signet 3255142 the 2551 magmeter flow sensor, 420 ma, 4. Signet 2551 magmeter flow sensor description the signet 2551 magmeter is an insertion style magnetic flow sensor that features no moving parts. Signet 73007524 power supply is used with the signet 2551 magmeter flow sensor and has innovative terminals with special spring loaded screws making installation as easy as pushing down and turning with a screwdriver. The sensor shall have a builtin display for calibration and flow rate indication with push button programming and. Output options include a traditional frequency signal, a serial data digital s3l output, and a 4 to 20 ma output. Here are a few tips that signet recommends for this type of usage. The signet 2552 magmeter features allstainless steel construction. Signet 2552 metal magmeter flow sensor the signet 2552 metal magmeter from georg fischer features allstainless steel construction. Sep 26, 2016 features of the gf signet 2551 insertion magnetic flow meter. Quick start guide this manual contains the general installation, wiring and calibration data for the signet 2551 xx11 magmeter with frequency or digital s3l data output, and for the signet 2551 xx12 magmeter with 4 to 20 ma output. The 2551 requires a full pipe and a fully developed turbulent flow profile for. M 0415 operating instructions description the 2551 magmeter measures the.
Signet 2552 magmeter flow sensors all stainless steel. Npt pipe outlets, and is adjustable to fit pipes from dn50 to dn2550 2 to 102. Wear safety goggles or faceshield during installationservice. Signet 2551 display magmeter safety instructions 1. The signet 2551 magmeter is an insertionstyle magnetic flow sensor. Signet 2552 metal magmeter flow sensors indianapolis. Use the 30232 setup tool to change the factory settings in the unit.
The pvdf nosepiece and fkm orings are the only other wetted materials. The patented sensor design is available in corrosionresistant materials to provide longterm reliability with minimal maintenance costs. For the 25523 the 112 inch process connection is standard and the 114 inch is available as a special order. Magmeter flow sensor type 2551 the 2551 magmeter is an insertion style magnetic flow sensor that features no moving parts. The signet 2551 magmeter is an insertion style magnetic flow sensor without any moving parts. The signet 2552 metal magmeter features allstainless steel construction.
Signet 2552 metal magmeter flow sensors process flow. Signet 2551 magmeter flow sensor available from flowquip. Gf signet 2551 magmeter flow sensor manual alpha controls. Wetted material combinations include pp316 ss, pvdfhastelloyc and pvdftitanium. If the piping system has entrained air pockets, take steps to locate the sensor so the air pockets will not contact the electrodes. The patented sensor design is available in a variety of corrosionresistant materials to provide longterm reliability and minimal maintenance costs. If you find this video helpful, please like us for more information please visit. The patented sensor design is available in corrosionresistant materials to provide longterm reliability rial options include pp with stainless steel, pvdf with stainless steel, pvdf. All versions are constructed of corrosionresistant materials to provide longterm reliability with minimal maintenance costs. Signet 2551 magmeter flow sensor horizon pool supply. The signet 2551 magmeter is an insertionstyle magnetic flow sensor that features no moving parts.
Features of the gf signet 2551 insertion magnetic flow meter. This manual contains the general installation, wiring and calibration data for the signet. Signet 2551 magmeter flow sensor industrial controls. Dec 19, 2016 the signet 2551 magmeter is an insertion style magnetic flow sensor that features no moving parts. Signet 73007524 power supply for signet 2551 magmeter flow. Gf signet 2551 magmeter flow sensor blind user manual.
Make sure that the sensor tip remains in liquid at all times. Signet 2551 magmeter flow sensor process flow industrial. May 20, 2011 magmeter flow sensor type 2551 the 2551 magmeter is an insertion style magnetic flow sensor that features no moving parts. All versions of the 2551 are constructed of corrosionresistant materials to provide longterm reliability with minimal maintenance costs.
Gf signet model 2551 magmeter flow sensor, part number 32551. Utilizing the comprehensive line of signet installation fittings, sensor alignment and insertion depth is automatic. Gf signet 3255142 the 2551 magmeter flow sensor, 420 ma. Gf signet 3255111 the 2551 magmeter flow sensor, frequency. Shop for the gf signet 2551 magmeter and other magmeters at instrumart. The patented sensor design is available in corrosionresistant materials. Gf signet 2551 magmeter flow sensor blind user manual 12. The gf signet 2551 magmeter is an insertion style magnetic flow sensor without any moving parts. Do not exceed maximum temperaturepressure speci cations.
Signet 2551 magmeter flow sensor nancrede engineering. Signet 2551 blind magmeter universal flow monitors. Gf signet 2551 magmeter intro and configuraton youtube. The signet 2551 magmeter is an insertion style magnetic flow sensor that features no moving parts.
Flow meters for commercial swimming pools signet 2551 magmeter pool flow sensors signet 2551 magmeter flow sensors signet 2551 magmeter flow sensors. Signet 2551 magmeter pool flow sensors halogen supply. Utilizing the comprehensive line of signet installation fittings, sensor alignment and insertion depth are automatic. The patented sensor design is available in corrosion resistant materials to provide longterm reliability with minimal maintenance costs. Each integral system features a nema rated 4xip65 9900 transmitter, which provides a local and easy to read lcd display.
This manual contains the general installation, wiring and calibration data for the signet 2551xx11 magmeter with frequency or digital s. Gf signet 2551 magmeter with display manual pdf 443 kb gf. The gf signet 2551 magmeter flow sensor is an insertionstyle magnetic flow sensor that features no moving parts. Use together with the signet installation fittings on page 747 for automatic sensor alignment and insertion depth. Npt pipe outlets, and is adjustable to fit pipes from dn50 to dn2550 2 to 102 in. Depressurize and vent system prior to installation or removal.
Gf signet 2551 operating instructions manual pdf download. The patented sensor design is available in a variety of corrosion resistant materials to provide longterm reliability and minimal maintenance costs. Signet 2551 magmeter flow sensor process flow industrial supply. Corrosion resistant insertion magmeter with optional display, accurate measurement. Signet has combined the 9900 smartpro transmitter with the 2551 magmeter flow sensor to create integral systems that are easy to order and simple to install. Table of contents english signet 2551 display magmeter 32551. Quick start guide this manual contains the general installation, wiring and calibration data for the signet 2551 xx11 magmeter with frequency or serial data output, and for the signet 2551 xx12 magmeter with currrent output. Output options include a traditional frequency signal, a serial data digital s 3 l output, and a 4 to 20 ma output. The 2551 magmeter measures the flow rate in a full pipe by monitoring the voltage produced when the conductive. This manual contains the general installation, wiring and calibration data for the signet 2551 xx11 magmeter with frequency or digital s. Magmeter flow sensor type 2551 georg fischer signet. L data output, and for the signet 2551xx12 magmeter with 4 to 20 ma output.
Gf signet model 2551 magmeter flow sensor, part number 3. The patented sensor design is available in corrosion resistant. The signet 2551 magmeter is an insertion style magnetic. Output options include a traditional frequency signal, a serial data digital output, and a 420 ma output. L data output, and for the signet 2551 xx12 magmeter with 4 to 20 ma output. Gf signet insertion magmeter flow sensors from davis. The 2551 magmeter measures the ow rate in a full pipe by monitoring the voltage produced when the conductive uid moves th rough a magnetic eld. The pvdf nosepiece and fpm orings are the only other wetted materials. Material options include pp with stainless steel, pvdf with hastelloyc, or pvdf with titanium. Signet 2551 magmeters offer many output options of frequencydigital s3l or 4 to 20 ma which are available on both the blind and display versions.
1231 1418 1336 535 903 635 582 1093 770 1135 1521 789 1106 1349 1551 1426 1291 655 796 141 1439 1271 1439 200 610 641 1217 294 1102 720